⚠️ Before proceeding, make sure your environment meets the Requirements, and finish the host preparation for shared RDMA mode in Host preparation.
Configure k8s-rdma-shared-dev-plugin
First, configure k8s-rdma-shared-dev-plugin to discover RDMA shared device resources on each host and report them to kubelet.
Edit the following ConfigMap to create 8 RDMA shared device resources, each affinitized to a GPU. For detailed configuration, refer to the official documentation.
$ kubectl edit configmap -n spiderpool spiderpool-rdma-shared-device-plugi
....
config.json: |
{
"periodicUpdateInterval": 300,
"configList": [
{
"resourcePrefix": "spidernet.io",
"resourceName": "shared_cx5_gpu1",
"rdmaHcaMax": 100,
"selectors": { "ifNames": ["enp11s0f0np0"] }
},
....
{
"resourcePrefix": "spidernet.io",
"resourceName": "shared_cx5_gpu8",
"rdmaHcaMax": 100,
"selectors": { "ifNames": ["enp18s0f0np0"] }
}
]
After the configuration is applied, check node allocatable resources to confirm each node reports 8 RDMA device resources.
$ kubectl get no -o json | jq -r '[.items[] | {name:.metadata.name, allocable:.status.allocatable}]'
[
{
"name": "ai-10-1-16-1",
"allocable": {
"cpu": "40",
"pods": "110",
"spidernet.io/shared_cx5_gpu1": "100",
"spidernet.io/shared_cx5_gpu2": "100",
...
"spidernet.io/shared_cx5_gpu8": "100",
...
}
},
...
]
Create Spiderpool resources
Create CNI config and IPPool
$ cat <<EOF | kubectl apply -f -
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderIPPool
metadata:
name: gpu1-net11
spec:
gateway: 172.16.11.254
subnet: 172.16.11.0/16
ips:
- 172.16.11.1-172.16.11.200
---
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: gpu1-macvlan
namespace: spiderpool
spec:
cniType: macvlan
rdmaResourceName: spidernet.io/shared_cx5_gpu1
macvlan:
master: ["enp11s0f0np0"]
ippools:
ipv4: ["gpu1-net11"]
EOF
By default, the Pod NIC MTU is the same as the Macvlan interface MTU. In some scenarios, you may want to customize Pod MTU:
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: gpu1-macvlan
namespace: spiderpool
spec:
cniType: macvlan
macvlan:
master: ["enp11s0f0np0"]
rdmaResourceName: spidernet.io/shared_cx5_gpu1
mtu: 1480
ippools:
ipv4: ["gpu1-net11"]
Note: MTU must not be greater than the MTU of the Macvlan master NIC, otherwise the Pod cannot be created.
Create a test application
-
Create a DaemonSet on specified nodes
In the following example, annotation
v1.multus-cni.io/default-networkspecifies using the default Calico interface for control-plane communication. Annotationk8s.v1.cni.cncf.io/networksattaches 8 GPU-affinity interfaces for RDMA traffic, and requests 8 RDMA resources.Tip: Webhook-based automatic injection is supported. See Webhook-based Automatic RDMA Resource Injection.
$ helm repo add spiderchart https://spidernet-io.github.io/charts $ helm repo update $ helm search repo rdma-tools # run daemonset on worker1 and worker2 $ cat <<EOF > values.yaml # for china user , it could add these to use a domestic registry #image: # registry: ghcr.m.daocloud.io # just run daemonset in nodes 'worker1' and 'worker2' affinity: nodeAffinity: requiredDuringSchedulingIgnoredDuringExecution: nodeSelectorTerms: - matchExpressions: - key: kubernetes.io/hostname operator: In values: - worker1 - worker2 # macvlan interfaces extraAnnotations: k8s.v1.cni.cncf.io/networks: |- [{"name":"gpu1-macvlan","namespace":"spiderpool"}, {"name":"gpu2-macvlan","namespace":"spiderpool"}, {"name":"gpu3-macvlan","namespace":"spiderpool"}, {"name":"gpu4-macvlan","namespace":"spiderpool"}, {"name":"gpu5-macvlan","namespace":"spiderpool"}, {"name":"gpu6-macvlan","namespace":"spiderpool"}, {"name":"gpu7-macvlan","namespace":"spiderpool"}, {"name":"gpu8-macvlan","namespace":"spiderpool"}] # macvlan resource resources: limits: spidernet.io/shared_cx5_gpu1: 1 spidernet.io/shared_cx5_gpu2: 1 spidernet.io/shared_cx5_gpu3: 1 spidernet.io/shared_cx5_gpu4: 1 spidernet.io/shared_cx5_gpu5: 1 spidernet.io/shared_cx5_gpu6: 1 spidernet.io/shared_cx5_gpu7: 1 spidernet.io/shared_cx5_gpu8: 1 #nvidia.com/gpu: 1 EOF $ helm install rdma-tools spiderchart/rdma-tools -f ./values.yamlDuring creation of the Pod network namespace, Spiderpool will test gateway connectivity on the Macvlan interface. If all Pods start successfully, it indicates VF connectivity works and RDMA communication should be available.
-
Check the Pod network namespace
Enter any Pod and confirm there are 9 interfaces:
$ kubectl exec -it rdma-tools-4v8t8 bash kubectl exec [POD] [COMMAND] is DEPRECATED and will be removed in a future version. Use kubectl exec [POD] -- [COMMAND] instead. root@rdma-tools-4v8t8:/# ip a 1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000 link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 inet 127.0.0.1/8 scope host lo valid_lft forever preferred_lft forever inet6 ::1/128 scope host valid_lft forever preferred_lft forever 2: tunl0@NONE: <NOARP> mtu 1480 qdisc noop state DOWN group default qlen 1000 link/ipip 0.0.0.0 brd 0.0.0.0 3: eth0@if356: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1480 qdisc noqueue state UP group default qlen 1000 link/ether ca:39:52:fc:61:cd brd ff:ff:ff:ff:ff:ff link-netnsid 0 inet 10.233.119.164/32 scope global eth0 valid_lft forever preferred_lft forever inet6 fe80::c839:52ff:fefc:61cd/64 scope link valid_lft forever preferred_lft forever 269: net1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP group default qlen 1000 link/ether 3a:97:49:35:79:95 brd ff:ff:ff:ff:ff:ff inet 172.16.11.10/24 brd 10.1.19.255 scope global net1 valid_lft forever preferred_lft forever inet6 fe80::3897:49ff:fe35:7995/64 scope link valid_lft forever preferred_lft forever 239: net2: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP group default qlen 1000 link/ether 1e:b6:13:0e:2a:d5 brd ff:ff:ff:ff:ff:ff inet 172.16.12.10/24 brd 10.1.19.255 scope global net1 valid_lft forever preferred_lft forever inet6 fe80::1cb6:13ff:fe0e:2ad5/64 scope link valid_lft forever preferred_lft forever .....Check routing. Spiderpool tunes policy routes to ensure return traffic symmetry:
root@rdma-tools-4v8t8:/# ip rule 0: from all lookup local 32762: from 172.16.11.10 lookup 107 32763: from 172.16.12.10 lookup 106 32764: from 172.16.13.10 lookup 105 32765: from 172.16.14.10 lookup 104 32765: from 172.16.15.10 lookup 103 32765: from 172.16.16.10 lookup 102 32765: from 172.16.17.10 lookup 101 32765: from 172.16.18.10 lookup 100 32766: from all lookup main 32767: from all lookup default root@rdma-tools-4v8t8:/# ip route show table 100 default via 172.16.11.254 dev net1In the main routing table, ensure Calico/ClusterIP/local host traffic goes through the Calico interface:
root@rdma-tools-4v8t8:/# ip r show table main default via 169.254.1.1 dev eth0 172.16.11.0/24 dev net1 proto kernel scope link src 172.16.11.10 172.16.12.0/24 dev net2 proto kernel scope link src 172.16.12.10 172.16.13.0/24 dev net3 proto kernel scope link src 172.16.13.10 172.16.14.0/24 dev net4 proto kernel scope link src 172.16.14.10 172.16.15.0/24 dev net5 proto kernel scope link src 172.16.15.10 172.16.16.0/24 dev net6 proto kernel scope link src 172.16.16.10 172.16.17.0/24 dev net7 proto kernel scope link src 172.16.17.10 172.16.18.0/24 dev net8 proto kernel scope link src 172.16.18.10 10.233.0.0/18 via 10.1.20.4 dev eth0 src 10.233.119.164 10.233.64.0/18 via 10.1.20.4 dev eth0 src 10.233.119.164 10.233.119.128 dev eth0 scope link src 10.233.119.164 169.254.0.0/16 via 10.1.20.4 dev eth0 src 10.233.119.164 169.254.1.1 dev eth0 scope linkConfirm there are 8 RDMA devices:
-
Validate RDMA connectivity between cross-node Pods
In one Pod, start the service:
In another Pod, access the service:
Webhook-based Automatic RDMA Resource Injection
In the steps above, we demonstrated how to use SR-IOV technology to provide RDMA communication capabilities for containers in RoCE and Infiniband network environments. However, the process can become complex when configuring AI applications with multiple network cards. To simplify this process, Spiderpool supports classifying a set of network card configurations through annotations (cni.spidernet.io/rdma-resource-inject or cni.spidernet.io/network-resource-inject). Users only need to add the same annotation to the application, and Spiderpool will automatically inject all corresponding network cards and network resources with the same annotation into the application through a webhook. cni.spidernet.io/rdma-resource-inject annotation is only applicable to AI scenarios, automatically injecting RDMA network cards and RDMA resources. cni.spidernet.io/network-resource-inject annotation can be used not only for AI scenarios but also supports underlay scenarios. In the future, we hope to uniformly use cni.spidernet.io/network-resource-inject to support both of these scenarios.
This feature only supports network card configurations with cniType of [ macvlan, ipvlan, sriov, ib-sriov, ipoib ].
-
Currently, Spiderpool's webhook for automatically injecting RDMA network resources is disabled by default and needs to be enabled manually.
After enabling the webhook automatic injection of network resources, you can update the configuration by updating the podResourceInject field in configMap: spiderpool-config.
Specify namespaces that do not require RDMA network resource injection through
podResourceInject.namespacesExclude.Specify namespaces that require RDMA network resource injection through
podResourceInject.namespacesInclude. If neitherpodResourceInject.namespacesExcludenorpodResourceInject.namespacesIncludeis specified, RDMA network resource injection is performed for all namespaces by default.Currently, after completing the configuration change, you need to restart the spiderpool-controller for the configuration to take effect.
-
When creating all SpiderMultusConfig instances for AI computing networks, add an annotation with the key "cni.spidernet.io/rdma-resource-inject" or "cni.spidernet.io/network-resource-inject" and a custom value.
apiVersion: spiderpool.spidernet.io/v2beta1 kind: SpiderIPPool metadata: name: gpu1-net11 spec: gateway: 172.16.11.254 subnet: 172.16.11.0/16 ips: - 172.16.11.1-172.16.11.200 --- apiVersion: spiderpool.spidernet.io/v2beta1 kind: SpiderMultusConfig metadata: name: gpu1-sriov namespace: spiderpool annotations: cni.spidernet.io/rdma-resource-inject: rdma-network spec: cniType: macvlan macvlan: master: ["enp11s0f0np0"] enableRdma: true rdmaResourceName: spidernet.io/gpu1rdma ippools: ipv4: ["gpu1-net11"] -
When creating an AI application, add the same annotation:
Note: When using webhook-based injection, do not add other network configuration annotations (such as
k8s.v1.cni.cncf.io/networksandipam.spidernet.io/ippools) to the application, otherwise it may affect automatic injection.
-
After the Pod is created, you can observe that the Pod has been automatically injected with network annotations and RDMA resources:
... spec: template: metadata: annotations: k8s.v1.cni.cncf.io/networks: |- [{"name":"gpu1-sriov","namespace":"spiderpool"}, {"name":"gpu2-sriov","namespace":"spiderpool"}, {"name":"gpu3-sriov","namespace":"spiderpool"}, {"name":"gpu4-sriov","namespace":"spiderpool"}, {"name":"gpu5-sriov","namespace":"spiderpool"}, {"name":"gpu6-sriov","namespace":"spiderpool"}, {"name":"gpu7-sriov","namespace":"spiderpool"}, {"name":"gpu8-sriov","namespace":"spiderpool"}] .... resources: limits: spidernet.io/gpu1rdma: 1 spidernet.io/gpu2rdma: 1 spidernet.io/gpu3rdma: 1 spidernet.io/gpu4rdma: 1 spidernet.io/gpu5rdma: 1 spidernet.io/gpu6rdma: 1 spidernet.io/gpu7rdma: 1 spidernet.io/gpu8rdma: 1